Portable
Raynger¡¡3iTM Series
Infared Noncontact Themometer
¡¡No matter it is dark,hot or inaccessible,when
you need to measure the temperature, the new Raynger 3i
series infared themometers will meet your demand with their
three laser sighting methods or optical telescope sighting
Multiple
measurment functions
¡¡¡¡3i series only only can display the
maximum and minimum of the temperature without having to
contact the objects to be measured but also allow automatic
sounde alarming on high or low temperature.they can be used
where the target is smaller than that where PM series apply.1
seml.and 1.6 seml.response and the themometers special for
plastic(P7) and glass(G5) applications are also provided.
data recording,sandardized
output function
¡¡¡¡3i series not only provide
100-data point EMS memory function,but also can output recorded
data in form of analog or RS232(power provided by 4 No.5
alkaline batteries.
measurement
distance and the minimum target diameter(on the
basis of recieving 90% energy)
¡¡ 
¡¡¡¡¡¡¡¡¡¡¡¡DISTANCE:SNESOR TO OBJECT(mm)
¡¡¡¡¡¡¡¡¡¡¡¡FAR FIELD D:S=60.:1¡¡¡¡FOCUS POINT D:S=90:1
|

¡¡¡¡¡¡¡¡¡¡¡¡DISTANCE:SNESOR TO OBJECT(mm)
¡¡¡¡¡¡¡¡¡¡¡¡FAR FIELD D:S=30.:1¡¡¡¡FOCUS POINT D:S=50:1 |
¡¡ 
¡¡¡¡¡¡¡¡¡¡DISTANCE:SNESOR TO OBJECT(mm)
¡¡¡¡¡¡¡¡¡¡¡¡FAR FIELD D:S=23.:1¡¡¡¡FOCUS POINT D:S=25:1
|

¡¡¡¡¡¡¡¡¡¡¡¡DISTANCE:SNESOR TO OBJECT(mm)
¡¡¡¡¡¡¡¡¡¡¡¡FAR FIELD D:S=20.:1¡¡¡¡FOCUS POINT D:S=75:1 |

¡¡¡¡¡¡DISTANCE:SNESOR TO OBJECT(mm)
¡¡¡¡¡¡¡¡ ¡¡FAR FIELD D:S=40.:1¡¡¡¡FOCUS POINT D:S=75:1
|

¡¡¡¡DISTANCE:SNESOR TO OBJECT(mm)
¡¡¡¡¡¡¡¡ ¡¡FAR FIELD D:S=140.:1¡¡¡¡FOCUS POINT D:S=180:1 |

¡¡¡¡¡¡¡¡DISTANCE:SNESOR TO OBJECT(mm)
¡¡¡¡¡¡¡¡ ¡¡FAR FIELD D:S=100.:1¡¡¡¡FOCUS POINT D:S=120:1
|

¡¡¡¡¡¡¡¡¡¡DISTANCE:SNESOR TO OBJECT(mm)
¡¡¡¡¡¡¡¡ ¡¡FAR FIELD D:S=68.:1¡¡¡¡FOCUS POINT D:S=75:1 |
|
SPECIFICATION
|
LT
|
LR
|
1M
|
2M
|
P7
|
G5
|
|
collimator
|
Dual/cross laser
/telescope
|
single laser/telescope
|
single laser/telescope
|
single laser/telescope
|
dual laser
|
telescope
|
|
measurement
range
|
-30-1200¡æ
|
600-3000¡æ
|
200-1800¡æ
|
10-800¡æ
|
150-1800¡æ
|
|
response wavelengh
|
8-14 micron
|
1 micron
|
1.6 micron
|
7.9 micron
|
5.0 micron
|
|
detector
|
thermopile
|
silicon
|
arsenic, gallium, indium
|
thermopile
|
|
function
|
¡¡real-time data,minimum,maximum,average,difference,data
adjustment,alarming on high/low temperature,data recording,100-data
point ESM memory,ambient temperature
|
|
measurement
accuracy
|
¡À1%(1M£¬¡À0.5%)of reading,or ¡À1¡æ whichever
is greater at(ambient temperature 23¡æ¡À5¡æ)
|
|
repeatability
|
¡¡0.5% of reading or ¡À1¡æ whichever
is greater
|
|
LCD display
|
¡¡unit in 1¡æ£¬4-digit backlit LCD
|
|
response time(95%)
|
700ms
|
550ms
|
700ms
|
|
emmissivity
|
¡¡adjustable from 0.1to1.0
|
|
analog output
|
¡¡1mV/¡æ
|
|
digital output
|
¡¡RS232 9600 baud,output interval¡¡adjustable
from1to9999 seconds
|
|
power requirement
|
¡¡4 AA alkaline or rechargeable batteries
or 6-9VDC¡¤200mA
|
|
operating
temperature
|
¡¡0-50¡æ
|
|
storage temperature
|
¡¡-20¡æ-50¡æ without batteries
|
|
relative humidity
|
¡¡10-95%( non-condensing up to 30¡æ)
|
|
dimensions
/weight
|
¡¡208mm*257mm*71mm 794 gram(laser models)
¡¡244mm*257mm*71mm 1000 gram(scope models)
|
|
options 1
(must be specified at time of order)
|
¡¡NIST certification 3iLRSCL3 options
|
|
options 2
|
¡¡IBM compatible machine output digital
software/output recording printer,voltage adapters,analogy
printer cable, computer cable/variable brightness
filter/Data Temp 2 software
|
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡